UN38.3 T9-T13: The New Hazard Based Battery Testing Standards

A major shift is underway in global dangerous goods transportation. The United Nations Sub-Committee of Experts on the Transport of Dangerous Goods has introduced a comprehensive, hazard-based classification system. This crucial update introduces five new battery abuse tests designated as T9 through T13 to complement the existing UN 38.3 testing baseline.

The Core Baseline: The Existing UN 38.3 T1-T8 Tests

  • T1 (Altitude Simulation): Verifies structural integrity in low-pressure environments like unpressurized aircraft cargo holds.
  • T2 (Thermal Test): Rapidly cycles temperatures from extreme cold to high heat to assess seal and internal electrical integrity.
  • T3 (Vibration): Simulates continuous mechanical wear, shifts, and shocks encountered during rugged transit.
  • T4 (Shock): Replicates sudden, high-impact acceleration or deceleration from accidental dropping or transport collisions.
  • T5 (External Short Circuit): Evaluates whether the battery can safely withstand an external electrical short circuit without catching fire or dismantling.
  • T6 (Impact / Crush): Measures internal physical resilience against heavy physical mass deformation or crushing force.
  • T7 (Overcharge): Assesses the battery’s safety features during extreme overvoltage beyond its maximum rated charge limits.
  • T8 (Forced Discharge): Forces electrical discharge back through a cell to evaluate its internal structural limits against abuse.

The New Frontier: Introducing Tests T9 to T13

Once robustness is demonstrated through the baseline tests, products enter the new hazard-based assessment tier. Under this updated framework, a cell or battery pack will face a maximum of three new tests tailored precisely to its product architecture.

T9 & T11: Propagation of Thermal Runaway

Test T9 is conducted on individual cells, whereas Test T11 is applied directly to multi-cell battery packs. These evaluations determine whether a controlled thermal runaway event inside a singular unit will catastrophically propagate to adjacent cells.

T10 & T12: Gas Volume Measurement

Triggered on an “as-needed” basis, Test T10 measures cell gas release, while Test T12 calculates the total gas volume emitted by a battery pack. This quantifies the precise volume of emissions pushed out during an emergency venting phase.

T13: Gas Flammability Limit Test

Applicable to both individual cells and completed battery packs when requested, Test T13 establishes the precise flammability and composition profile of the vented gases. This determines whether the emissions present an explosive hazard during a transit failure.

The New Frontier: Introducing Tests T9 to T13

Following a designated regulatory transition period where legacy codes (UN 3480, UN 3481, UN 3090, UN 3091) remain valid, all products will eventually transition to a hazard grading scale from Type A (Most Severe) to Type F (Least Severe). Proper shipping names and newly issued UN numbers are determined by battery chemistry combined with the unit’s specific behaviour at its transport SOC:

Useful external references:
Reference standards:
Hazard Type Technical Classification Criteria UN Number (Sodium & Li-Ion) UN Number (Lithium Metal)
Type A High-risk profile exhibiting thermal propagation, severe heat hazards, and large volumes of flammable and toxic gas exceeding 25L or 500L boundaries. UN 3600 UN 3601
Type B Units generating notable heat hazards alongside a large quantity of flammable gas, regardless of propagation limits. UN 3602 UN 3603
Type C Profiles marked by high heat emissions and a large quantity of non-flammable gas falling between 25L and 500L. UN 3604 UN 3605
Type D Characterised by no thermal propagation, standard heat levels, and flammable gas managed strictly between 0.25L and 25L limits. UN 3606 UN 3607
Type E Safer configurations demonstrating no propagation, normal heat, and flammable gas volumes successfully restricted under 0.25L. UN 3608 UN 3609
Type F The safest tier, reserved for cells and packs displaying chemical content hazards only, with zero propagation, zero heat, and minimal gas below 0.25L. UN 3610 UN 3611

Navigating the New Packing Instructions (PI 940 - PI 943)

The specific hazard type your product receives dictates the logistical packaging requirements needed for compliant transport. To meet compliance, logistics managers must officially track cell/battery SOC parameters or build physical propagation prevention features directly into the product casing:

  • PI 940 (Applicable to Hazard Types E & F)

    Designed for lower-risk profiles. Allows general transport provisions or strong, rigid outer packaging/casings. Enforces a strict rule against electrical short circuits or accidental activation.

     

  • PI 941 (Applicable to Hazard Types A, B, C, & D)

    The core standard for standard configurations and configurations exceeding 12 kg. Mandates the use of robust Packing Group II (PG II) certifiable outer boxes or industrial casings.

     

  • PI 942 (Applicable to Hazard Types A & B)

    Focuses on advanced hazard mitigation. Requires explicit, complementary packaging layouts that use physical separations or mechanical isolation methods designed to halt thermal runaway propagation entirely.

     

  • PI 943 (Applicable to Hazard Types A, B, & C)

    The highest tier of containment. Demands specialized non-combustible and non-conductive packaging materials to safely isolate high-volume or highly flammable thermal venting events.

Navigating Special Provision 376 (SP376) for Damaged or Defective Batteries

When a cell or battery is identified as damaged or defective, it completely bypasses standard transport procedures and falls under the strict mandates of Special Provision 376 (SP376). Because compromised lithium batteries present a significantly elevated risk of fire or explosion, logistics managers cannot treat them as regular cargo.

Compromised batteries are chemically unstable, subjecting them to rigorous testing conditions like vibration, thermal shock, or extreme overcharge would be highly hazardous. Instead, shippers substitute standard UN 38.3 compliance protocols with the strict containment requirements of SP376, moving from standard packing instructions to specialized emergency packing tracks (P908 or P911)

P908/LP904: Stable Damaged Batteries- Physically compromised units (e.g., dented, cracked, or deformed casings) that remain chemically stable and are not liable to react violently during normal transit.

P911/LP906: Unstable / High-Risk Batteries- Critically compromised units liable to rapidly disassemble, produce flames, generate dangerous heat levels, or emit toxic and flammable gases.

Battery Testing in the UK & Ireland

Resonate testing provides high quality fire, mechanical, and environmental test solutions and certification services across a wide range of industrial sectors. From Primes to SME’s, Resonate Testing provides a bespoke and tailored service to our clients.

Send your battery requirement for engineer review

Use the contact route to share the requirement, test profile, drawings or specification for review.

Contact Form

Whether you’re looking to contact us for the first time or have another testing requirement,  we’d love to hear from you.