Humidity Testing UK & Ireland | Climatic, Damp Heat & Temperature-Humidity Cycling

Humidity Testing for Product Reliability, Environmental Qualification and Standards Compliance

Resonate Testing supports humidity, damp heat and combined temperature-humidity testing for aerospace, defence, electronics, rail, automotive, packaging, industrial and advanced engineering products using IEC 60068, MIL-STD-810, RTCA DO-160 and customer-defined requirements.

Your Test Facilitator. Not simply a Test Facility.

Resonate provides humidity testing and climatic environmental testing for products that need to withstand moisture, condensation and changing temperature conditions. Our chambers support humidity control from 10% to 98% RH, with temperature capability from sub-zero conditions through high-temperature exposure depending on the required profile and chamber selected.

What is humidity testing?

Humidity testing exposes a product, assembly or material to controlled moisture and temperature conditions so engineers can assess reliability, corrosion risk, electrical performance, coating behaviour and long-term environmental durability.

  • Damp heat steady state: Holds defined temperature and relative humidity conditions to assess moisture resistance over time.

  • Damp heat cyclic: Cycles temperature and humidity to encourage condensation and reveal weaknesses in sealing, materials or finishes.

  • Combined temperature-humidity cycling: Uses changing temperature and RH profiles to simulate more demanding climatic exposure.

  • Functional checks: Allows agreed electrical, visual or performance checks before, during or after exposure.

  • Standards support: Supports IEC 60068 damp heat methods, MIL-STD-810 humidity and RTCA DO-160 humidity requirements.

  • Evidence generation: Produces controlled test records, observations and reporting to support qualification, acceptance or development decisions.

Related testing services:

Humidity Testing in the UK & Ireland

Ready to plan your humidity testing campaign? Send your standard, humidity profile, product details or customer specification for engineer review and receive guidance on chamber suitability, monitoring, dwell times and reporting requirements.

Not sure which humidity profile applies?

Humidity requirements can vary significantly by sector, standard and product risk. Whether you are preparing for qualification, validating an engineering build, investigating moisture sensitivity or planning customer acceptance, an early engineering review can help identify the most practical route through climatic testing.

Share your product description, applicable standard, temperature and humidity profile, operating condition, dimensions, mass, monitoring needs and reporting expectations. Resonate Testing can review chamber suitability, test setup and evidence requirements before quotation.

  • Steady-state damp heat and cyclic damp heat planning

  • Electronics, aerospace, defence, rail, automotive and industrial product support

  • Functional monitoring and visual inspection planning

  • Standards and customer requirement review

  • Integrated humidity, temperature cycling, altitude, salt fog, water ingress, vibration and shock testing campaign planning

IEC 60068, MIL-STD-810, RTCA DO-160 and customer requirements: Why standards matter

Humidity testing is normally planned around the product’s operating environment, failure risks, known in-field issues or applicable qualification route. Depending on the programme, requirements may reference IEC 60068 damp heat methods, MIL-STD-810 Method 507, RTCA DO-160 Section 6 or a customer-specific environmental profile.

The objective is not simply to place an item in a humid chamber. The objective is to generate evidence that is relevant to moisture exposure, condensation risk, corrosion mechanisms, electrical insulation performance, seal integrity, coating behaviour and post-test functionality.

Humidity campaigns are typically tailored from the standard method and product requirement. Temperature level, relative humidity, cycle count, dwell duration, operating state, monitoring, recovery conditions and inspection points should be reviewed before testing begins.

Early review of the applicable standard can reduce rework, improve traceability and help ensure the resulting test evidence aligns with stakeholder expectations.

Standard / Guidance Primary Focus Typical Relevance to Testing
IEC/EN 60068-2-78 Damp heat, steady state Damp heat steady-state testing for products exposed to sustained humidity.
IEC/EN 60068-2-30 Damp heat, cyclic Damp heat cyclic testing for condensation and cyclic humidity exposure.
IEC/EN 60068-2-38 Composite temperature / humidity cyclic Combined temperature-humidity cyclic testing for more demanding climatic profiles.
MIL-STD-810 Method 507 Humidity Humidity testing for defence and ruggedised equipment environmental evaluation.
RTCA DO-160 Section 6 Humidity Humidity requirements for airborne equipment qualification programmes.
Customer specifications Project-specific humidity requirements Acceptance criteria, monitoring requirements and reporting expectations.
Your Test Facilitator, Not Simply a Test Facility

What to provide before a humidity test quotation

  • Product dimensions, drawings, mass and handling constraints

  • Applicable standard, customer specification or qualification requirement

  • Required temperature and relative humidity set points  and tolerances

  • Cycle count, ramp conditions, dwell duration and total exposure time

  • Operating or non-operating condition during exposure

  • Power, signal, data logging or sensor monitoring requirements

  • Functional checks, frequency interim inspections (if required) and post-test inspection criteria

  • Battery, hazardous material, stored-energy or moisture-sensitive safety information

  • Condensation limits, sealing concerns, corrosion indicators or material compatibility risks

  • Reporting, photographic evidence and witness requirements

Humidity testing capability

Resonate Testing provides climatic chamber capability for steady-state humidity, damp heat cyclic and combined temperature-humidity cycling. Available humidity capability supports 10% to 98% RH, with chamber temperature capability from sub-zero conditions up to +180°C depending on the selected chamber and profile.

Typical planning inputs include the applicable standard or customer specification, temperature and RH profile, cycle count, dwell duration, unit dimensions and mass, operating or non-operating condition, functional monitoring needs, inspection points, report requirements and programme timescale.

Specification Capability
Chamber Type Climatic chamber for humidity, damp heat and temperature-humidity cycling
Humidity Range 10% to 98% RH, depending on chamber selection and test profile
Temperature Capability Sub-zero conditions up to +180°C, depending on chamber and humidity profile
Supported Profiles Steady-state damp heat, cyclic damp heat and combined temperature-humidity cycling
Typical Standards IEC/EN 60068-2-30, IEC/EN 60068-2-38, IEC/EN 60068-2-78, MIL-STD-810 Method 507 and RTCA DO-160 Section 6
Test Inputs Temperature and RH profile, cycle count, dwell duration, operating condition, dimensions, mass and monitoring requirements, tolerances
Specimen Setup Fixture, cable routing, power state, monitoring channels and inspection access agreed during planning
Functional Monitoring Powered operation, signal checks, electrical monitoring or interim inspections can be planned where required
Typical Outputs Achieved temperature and humidity records, observations, inspection notes, functional check results where agreed and test report outputs
Test Planning Support Standards review, chamber suitability, profile feasibility, dwell strategy, monitoring, safety planning and reporting requirements

How a humidity test campaign works

  1. Plan: Review the requirement, standard, temperature and RH profile, acceptance criteria, safety considerations and observations required.

  2. Prepare: Confirm chamber suitability, fixtures, cable routing, instrumentation, monitoring points and functional checks.

  3. Mount and instrument: Install the product, connect agreed channels and verify the setup before the climatic chamber is closed.

  4. Condition: Stabilise the chamber at the agreed temperature and humidity conditions before dwell or cycling begins.

  5. Cycle and dwell: Run the agreed humidity profile, including RH set points, ramps, temperature set points and dwell periods.

  6. Functional checks: Power or operate the hardware at defined points when this is part of the agreed plan.

  7. Review and report: Check achieved conditions, observations, plots, photographs and agreed outputs.

Humidity Terms

Relative Humidity

Relative humidity, or RH, is the amount of water vapour in the air compared with the maximum amount the air can hold at a given temperature. Humidity tests usually define exposure conditions as a temperature and RH set point.

Dwell Time

Dwell time is the period a product remains at a defined temperature and humidity condition after the chamber has reached the agreed set points.

Cycling

Temperature-humidity cycling exposes a product to changing temperature and RH conditions over repeated cycles. The plan should define the set points, ramps, dwell periods, cycle count and total exposure time.

Steady-state damp heat

Steady-state damp heat holds the product at a stable temperature and humidity condition for the agreed exposure period. It is commonly used to assess moisture resistance and material stability.

Condensation

Condensation occurs when moisture forms on a surface because the surface temperature and surrounding humidity conditions allow water vapour to condense. If condensation limits matter, they should be stated before testing.

Monitoring

Monitoring may include temperature, relative humidity, sensor channels, data logging, power, signals and functional checks. The required channels and inspection points should be confirmed before the chamber is closed.

Reporting

Typical outputs may include achieved temperature and humidity records, observations, plots, photographs, inspection notes, functional check results where agreed and the agreed test report or data pack.

Condensation, corrosion and moisture-sensitive material considerations

During humidity testing, moisture can affect electrical insulation, coatings, seals, adhesives, polymers, metals and exposed interfaces. Condensation risk should be reviewed early when the profile includes cyclic damp heat, rapid temperature changes or recovery periods.

If the product includes moisture-sensitive materials, electronics, coatings, bonded joints, optical surfaces or corrosion-critical finishes, define inspection points, acceptance criteria, functional checks and any limits on visible condensation before quotation.

Humidity, damp heat and climatic testing in one coordinated campaign

Products exposed to moisture often need more than one climatic assessment. Coordinating humidity, damp heat, temperature cycling and related environmental checks within one campaign helps reduce handover friction, align setup decisions and keep evidence traceable across the full programme.

For projects that also need salt fog, rain, water ingress or other environmental testing, review the related services before finalising the campaign sequence.

Fast. Flexible Accessible.

What you will receive after your humidity testing

Outputs are agreed before the test so the evidence matches the programme need. A typical package may include:

  • Recorded temperature, relative humidity and agreed monitoring data

  • Plots showing the achieved humidity profile, ramp periods, dwell points and RH conditions

  • Observations from setup, test execution and post-test review

  • Photographic evidence where agreed

  • Confirmation of functional checks completed during the profile

  • An agreed test report or data pack aligned to the quotation scope

Humidity Testing FAQ's

Basic

Planning

Outputs

Send your humidity testing requirements for engineer review

Book testing for products, components, enclosures, electronics, packaging and industrial equipment. Use the contact route to share the requirement, drawings, specification, test profile, customer standard or failure concern for review.