EUROCAE ED-14G is an environmental qualification standard for airborne equipment. It defines test categories and laboratory procedures for climatic, mechanical, electrical and electromagnetic conditions that equipment may experience during aircraft operation.
ED-14G is the European counterpart to RTCA DO-160G. It supports qualification evidence, but it is not a certification regulation and a successful test does not automatically approve an article or aircraft installation. The applicable certification basis, ETSO or TSO, contract and approved compliance plan determine how evidence is accepted.
| Item | Practical meaning |
|---|---|
| Application | Equipment intended for installation in or on aircraft |
| Purpose | Environmental qualification under declared conditions |
| Full title | Environmental Conditions and Test Procedures for Airborne Equipment |
| US counterpart | RTCA DO-160G |
| Core approach | Select applicable sections and installation-based categories |
| Qualification record | Environmental Qualification Form, procedure and report |
| Key limitation | Successful testing is not automatic certification or installation approval |
No. ED-14G testing generates environmental qualification evidence; it does not independently certify equipment or approve an aircraft installation. Environmental qualification is one part of a wider evidence chain shared by the equipment manufacturer, installer, design organisation, laboratory and authorised compliance personnel.
| Layer | Role |
|---|---|
| Airworthiness and article requirements | Define what must be demonstrated and the approval route. |
| ED-14G / DO-160G | Provide environmental categories and laboratory methods. |
| Qualification or certification plan | Identifies the accepted means of compliance and applicable sections. |
| Environmental Qualification Form | Records the tested sections, categories and declarations. |
| Qualification test procedure | Controls the article, setup, sequence, operation, monitoring and acceptance criteria. |
| Test report | Records achieved conditions, results, anomalies and deviations. |
| Installation assessment | Confirms that the evidence represents the intended aircraft installation. |
| Authorised finding | Determines regulatory or programme acceptance. |
Sections 1–3 establish the common purpose, definitions and test conditions. Sections 4–26 address individual environmental disciplines. Only the sections relevant to the equipment and installation should be selected.
| Section | Environmental discipline | What the programme should establish |
|---|---|---|
| 4 | Temperature and altitude | Installation zone, operating and survival temperatures, altitude, decompression, overpressure and cooling needs. |
| 5 | Temperature variation | Applicable rate category, operating checks, cycling and condensation control. |
| 6 | Humidity | Moisture exposure, condensation risk, operation and post-exposure checks. |
| 7 | Operational shock and crash safety | Functional shock, structural loads, mounting integrity and safety criteria. |
| 8 | Vibration | Aircraft type, installation zone, mounting, axes, profile, duration and monitoring. |
| 9 | Explosion proofness | Potential explosive atmosphere, ignition risks and applicable specialist route. |
| 10 | Waterproofness | Expected water exposure, enclosure arrangement and functional assessment. |
| 11 | Fluids susceptibility | Installation-relevant fluids, application method, temperature, duration and recovery. |
| 12–14 | Sand and dust; fungus; salt spray | Material, location and exposure relevance, plus sequence constraints. |
| 15 | Magnetic effect | Permissible influence on aircraft magnetic instruments. |
| 16–19 | Power and conducted susceptibility | Power architecture, cable configuration, grounding, operating modes and limits. |
| 20–21 | RF susceptibility and emissions | Category, frequency coverage, cable setup, performance criteria and specialist facilities. |
| 22–23 | Lightning effects | Installation wiring, shielding, pin injection or cable tests, waveforms and direct-effects applicability. |
| 24–25 | Icing and electrostatic discharge | Exposure scenario, equipment accessibility and operational response. |
| 26 | Fire and flammability | Applicable material or equipment objective, category and acceptance route. |
Category X indicates that compliance has not been demonstrated for that environmental discipline. It should not be treated as a pass or as evidence that the section is irrelevant.
No. The required sections and categories depend on the equipment function, aircraft type, installation zone, mounting arrangement, operating state and approved qualification strategy. Applying every section—or automatically choosing the harshest category—can produce irrelevant evidence and unnecessary programme risk.
Use the contact route to share the requirement, test profile, drawings or specification for review.
Whether you’re looking to contact us for the first time or have another testing requirement, we’d love to hear from you.