AS6826 Powerplant Fire Test Standard

Introduction

Aircraft powerplant fire testing has historically relied on a combination of FAA advisory material, legacy engineering reports, SAE standards, ISO guidance and certification-project precedent. These sources established a strong technical foundation, but they also permitted differences in burner configuration, flame calibration, test-article representation, operating boundary conditions and acceptance criteria.

AS6826 was issued by SAE International in April 2025 to provide a more consistent and prescriptive framework for demonstrating compliance with powerplant installation and propulsion-system component fire-protection requirements. Its development followed a March 2018 FAA request for SAE International to create industry standards supplementing FAA AC 20-135 Change 1. The work was undertaken by the SAE A-22 Fire Protection and Flammability Testing Committee with participation from industry and aviation certification authorities.

The standard defines fire-test methodologies, burner requirements, temperature and heat-transfer calibration procedures, representative test conditions, boundary-condition assessment and component-specific pass/fail criteria. Its purpose is to reduce unnecessary variation between certification programmes and improve the quality, repeatability and defensibility of fire-test evidence.

AS6826 does not replace applicable airworthiness regulations or remove the need for certification-authority agreement. Applicants remain responsible for establishing the applicable requirements, proposed means of compliance, test configurations and acceptance criteria for each certification project. Early coordination is particularly important where an installation includes unusual geometry, non-conventional propulsion, hybrid-electric systems, novel materials or project-specific boundary conditions.

What Is AS6826?

Definition

AS6826 is an SAE Aerospace Standard providing guidance and acceptable fire-test methods for powerplant and auxiliary power unit components and installations. It addresses the demonstration of fire-resistant and fireproof performance through controlled exposure to a calibrated standard flame.

The standard covers:

  • Fire-test planning and reporting.

  • Representative test articles and installation conditions.

  • Acceptable liquid-fuel burners.

  • Flame-temperature calibration.

  • Flame heat-transfer-rate calibration.

  • Test boundary conditions.

  • Fire-intended functions.

  • Component-specific pass/fail criteria.

  • Residual flames, outgassing and backside ignition.

  • Firewalls, nacelle hardware, fluid systems, controls and fire-detection equipment.

Purpose

AS6826 is intended to:

  • Harmonise powerplant fire-testing practices.

  • Reduce unnecessary variation between test facilities.

  • Establish repeatable burner-calibration methods.

  • Improve consistency in boundary-condition selection.

  • Define clearer pass/fail criteria.

  • Generate stronger certification evidence.

  • Supplement FAA AC 20-135 Change 1.

  • Support coordination between applicants, suppliers, test laboratories and certification authorities.

Where It Fits in an Aerospace Programme

Programme stage AS6826 application
Design Identify designated fire zones, fire-critical components, applicable regulations and required fire-intended functions.
Manufacturing Produce conforming or representative test articles using production materials, processes, interfaces and installation details.
Qualification testing Conduct fire-resistant or fireproof tests using calibrated burners and justified boundary conditions.
Certification verification Use approved plans, procedures, calibration records, test data and reports to demonstrate the agreed means of compliance.
Flight readiness Close certification findings and confirm that the approved fire-protection design supports continued safe operation following a fire event.

AS6826 applies to certification fire testing. It should not be treated as a generic material flammability standard or as a substitute for system safety assessment.

Why Is AS6826 Important?

Risk Reduction

A fire test can produce a technically misleading result if the burner is incorrectly calibrated, the test article is unrepresentative or the applied operating conditions are less severe than the installed aircraft environment. AS6826 reduces this risk by requiring a structured justification of the test article, flame, setup, critical exposure location, boundary conditions and acceptance criteria.

Compliance

The standard provides methods intended to support demonstration of applicable powerplant fire-protection requirements. However, the applicant must still identify the governing regulations and obtain agreement on the proposed means of compliance.

Compliance with AS6826 should therefore be viewed as part of a certification strategy, not as a stand-alone certificate of regulatory compliance.

Verification Confidence

Consistent calibration methods improve comparability between tests. AS6826 requires pre-test flame-temperature and heat-transfer-rate calibration, controlled burner settings during the test and post-test heat-transfer-rate validation before the burner is shut down.

These controls reduce uncertainty over whether a test article experienced the required fire severity.

Aircraft Safety Assurance

The standard focuses on fire-intended functions. A component may be required to contain fire, prevent hazardous leakage, remain attached, carry load, close a shut-off path, preserve drainage, maintain an alarm or prevent flame penetration.

The relevant function must be defined before testing because the required function determines both the test conditions and the pass/fail criteria.

How AS6826 Applies to Powerplant Fire Testing

Relevant Standards and Guidance

AS6826 draws upon, supplements or affects a wider body of fire-test documentation, including:

  • FAA AC 20-135 Change 1, Powerplant Installation and Propulsion System Component Fire Protection Test Methods, Standards, and Criteria.

  • FAA Powerplant Engineering Report No. 3A, Standard Fire Test Apparatus and Procedure.

  • ISO 2685, Aircraft environmental test procedure for airborne equipment, resistance to fire in designated fire zones.

  • SAE AIR1377, Fire Test Equipment for Flexible Hose and Tube Assemblies.

  • SAE AS1055, covering fire testing of flexible hose, tube assemblies, coils, fittings and similar system components.

  • SAE AS4273, covering fire testing of fluid-handling components.

  • SAE AS5127/2, covering aerospace firewall sealant flame-penetration testing.

  • SAE AS8028, covering powerplant fire-detection instruments.

  • Applicable FAA regulations, EASA Certification Specifications and supporting acceptable means of compliance.

AS6826 states that its text takes precedence over referenced material where a conflict exists within its defined application. It does not supersede applicable laws or regulations.

Tailoring Considerations

The standard is prescriptive, but test programmes remain installation-specific. Tailoring may be required for:

  • Aircraft category.

  • Engine or APU installation.

  • Designated fire-zone geometry.

  • Test-article size and complexity.

  • Critical burner orientation.

  • Flame impingement location.

  • Fluid type, temperature, pressure and flow.

  • Vibration and mechanical loading.

  • Differential pressure.

  • Backside airflow.

  • Rotational speed.

  • Commanded or controlled functions.

  • Ground and flight operating conditions.

  • Engine-running and engine-shutdown phases.

  • Novel propulsion or energy-storage systems.

Tailoring must not be used to reduce test severity without an adequate engineering justification.

Customer and Certification-Authority Requirements

The applicant should obtain early agreement on:

  • Applicable regulations.

  • Fire-resistant or fireproof classification.

  • Proposed means of compliance.

  • Test-article representativeness.

  • Critical test conditions.

  • Burner orientation.

  • Boundary-condition values.

  • Pass/fail criteria.

  • Test deviations.

  • Required witnessing and conformity arrangements.

Novel configurations may require issue papers, Certification Review Items or equivalent authority coordination.

Typical AS6826 Fire-Test Process

Planning

  • Identify applicable regulations and certification requirements.

  • Determine whether the design requires fire-resistant or fireproof performance.

  • Define every fire-intended function.

  • Identify critical flame-application locations.

  • Assess ground and flight operating envelopes.

  • Determine worst-case boundary conditions.

  • Agree the means of compliance with the certification authority.

  • Prepare the fire-test plan and compliance matrix.

Preparation

  • Manufacture or select representative test articles.

  • Confirm configuration and conformity status.

  • Replicate production materials, joints, seals, fasteners and interfaces.

  • Install representative heat paths and heat sinks.

  • Configure operational pressures, flows, loads and functions.

  • Install calibrated instrumentation.

  • Verify test-facility safety controls.

  • Confirm video coverage of flame-side and backside behaviour.

Execution

  • Inspect and record the test configuration.

  • Warm up the burner.

  • Complete pre-test temperature calibration.

  • Complete pre-test heat-transfer-rate calibration.

  • Apply the defined boundary conditions.

  • Begin video and data recording.

  • Move the burner into the calibrated test position.

  • Conduct the required exposure.

  • Maintain or transition boundary conditions as defined.

  • Monitor leakage, flame penetration, backside ignition and fire-intended functions.

  • Observe the test article after burner withdrawal.

  • Complete post-test heat-transfer-rate validation before shutting down the burner.

Review

  • Assess the fire-intended functions.

  • Review flame penetration and burn-through.

  • Review leakage and fluid release.

  • Confirm load retention where applicable.

  • Examine backside ignition.

  • Record residual flame size, location and duration.

  • Examine outgassing, damage and deformation.

  • Review all deviations from the approved procedure.

Closure

  • Complete the fire-test report.

  • Include photographs and video references.

  • Attach calibration and validation data.

  • Document test-article conformity.

  • Confirm adherence to boundary conditions.

  • Record pass/fail conclusions against each criterion.

  • Close deviations with the certification authority.

  • Update the certification compliance matrix.

Key Activities in AS6826 Testing

Standard Flame

AS6826 defines the standard flame as having:

  • A minimum flame temperature of 2,000°F or 1,093°C.

  • A minimum heat-transfer rate of 4,500 Btu/h or 1,319 W when measured using the prescribed continuous-flow copper-tube apparatus.

The flame-temperature requirement and the heat-transfer-rate requirement are separate calibration controls. Both must be satisfied before testing.

Temperature Calibration

The standard requires:

  • A seven-thermocouple rake.

  • Exposed-junction Type K thermocouples.

  • A minimum recording rate of 0.5 Hz.

  • A minimum three-minute calibration period.

  • An individual average temperature of 2,000°F ±150°F for each thermocouple.

  • A minimum rake average temperature of 2,000°F across the five inner thermocouples.

Individual thermocouple averages above 2,150°F may be accepted as conservative, but they represent a more severe condition than the standard intends.

Heat-Transfer-Rate Calibration

The heat-transfer device uses a controlled water flow through a copper tube exposed to the flame. The calculated heat-transfer rate is based on water flow, density, specific heat capacity and measured inlet-to-outlet temperature rise.

Key controls include:

  • Water flow of 1.00 US gal/min ±0.05 US gal/min.

  • A minimum three-minute recording period.

  • A minimum sample rate of 0.5 Hz.

  • A pre-test average heat-transfer rate of at least 4,500 Btu/h.

  • No adjustment to burner settings after successful calibration.

Post-Test Validation

Post-test validation confirms that burner performance did not deteriorate during testing.

  • If the copper tube is cleaned before validation, the average must remain at or above 4,500 Btu/h.

  • If cleaning is impossible without shutting down the burner, the permitted validation threshold is 4,100 Btu/h.

  • Failure to achieve the applicable post-test threshold can invalidate the fire test and require repetition.

Fire-Resistant and Fireproof Exposure

Classification Minimum flame exposure
Fire resistant 5 minutes
Fireproof 15 minutes

For a fireproof test, the powerplant or APU is generally represented as running during the first five minutes. Shutdown or windmilling conditions may then apply during the remaining ten minutes, depending on the installation and approved test plan.

Operating Boundary Conditions

Each listed boundary condition must be assessed for applicability:

  • Induced vibration.

  • Mechanical or structural loading.

  • Differential pressure.

  • Backside airflow.

  • Commanded or controlled function.

  • Fluid pressure.

  • Fluid flow.

  • Fluid temperature.

  • Fluid-reservoir quantity.

  • Component rotational speed.

  • Test fluid.

The worst-case value for each applicable condition may occur at a different aircraft operating point. The test matrix must therefore demonstrate that every applicable worst-case condition is represented or conservatively enveloped.

Fire-Test Pass/Fail Considerations

Pass/fail criteria must be defined for the specific component and its fire-intended functions. Typical criteria include:

Firewalls

  • No burn-through.

  • No unacceptable flame penetration.

  • No backside ignition.

  • Continued load capability where applicable.

  • Leakage within approved limits.

  • Residual flames within acceptable limits.

  • Maintenance of the fire-intended function.

Flammable-Fluid Components

  • No external flammable-fluid leakage during exposure.

  • Continued operation of required fire-intended functions.

  • Maintenance of applicable pressure and flow conditions.

  • No failure of mounting provisions that could create an additional hazard.

Immediately after burner retraction, no leakage greater than weepage insufficient to form a drop is permitted for applicable flammable-fluid conveyance products.

Shut-Off Valves

A fire-resistant shut-off valve may be required to close following the initial five-minute exposure without external leakage.

A fireproof shut-off valve may additionally be required to remain closed and pressurised during a further ten minutes of flame exposure.

Fire Detectors

The detector system must perform the defined fire-intended function during exposure. AS6826 distinguishes this installation-level function from the broader equipment qualification tests contained in AS8028.

Residual Flames

Residual flames may be acceptable where they:

  • Do not compromise the fire-intended function.

  • Do not violate another pass/fail criterion.

  • Are significantly smaller than the burner flame.

  • Do not propagate.

  • Show an overall reduction in intensity.

  • Self-extinguish within two minutes after burner removal.

Residual flames must be recorded by duration, size, quantity and video. System-level implications may require certification-authority review.

Common Risks and Challenges

Technical Risk

Incorrect burner calibration, damaged thermocouples, unsuitable instrumentation or poor burner positioning can invalidate a test.

Schedule Risk

A failed pre-test calibration, unacceptable post-test validation or uncontrolled deviation may require the complete test to be repeated.

Cost Risk

Large nacelle structures, firewalls, complex component installations and representative three-dimensional rigs can require substantial tooling, instrumentation and test-facility preparation.

Verification Risk

A test may be severe in one parameter but non-representative in another. Combining individually conservative values can also create an unrealistic configuration that changes the failure mechanism.

Documentation Risk

Weak configuration records, incomplete boundary-condition justification or unclear pass/fail criteria can make technically successful testing difficult to accept for certification.

Programme Risk

Late authority engagement can expose disagreement over the means of compliance after hardware, tooling and test plans have already been committed.

Best Practices

Define Fire-Intended Functions Early

State exactly what the component must do during and after exposure. Avoid generic wording such as “must survive the test”.

Use Representative Hardware

The test article should represent production materials, geometry, joints, penetrations, seals, fasteners, heat paths and installation constraints.

Assess Every Boundary Condition

Record why each AS6826 boundary condition is applicable or not applicable. Do not omit a condition without justification.

Establish the Worst-Case Operating Envelope

Assess the full normal operating ground and flight envelope. “Typical operation” is not necessarily the certification worst case.

Maintain Burner Configuration

Do not change burner fuel flow, airflow, geometry or settings after successful calibration and before post-test validation.

Protect Test Distance

Thermal deformation, rig movement or vibration must not change the calibrated distance between the burner and the critical test location.

Record Both Sides of the Test Article

Video coverage should detect flame-side behaviour, backside ignition, leakage, deformation, outgassing and residual flames.

Control Configuration and Conformity

Record test-article identity, drawings, build standard, materials, production processes, deviations and conformity status.

Agree Acceptance Criteria Before Testing

Pass/fail criteria should be measurable, observable and approved before the burner is lit.

Engage the Certification Authority Early

Early engagement reduces the risk of repeating tests because the authority disagrees with the configuration, boundary conditions or means of compliance.

A complete AS6826 compliance package may include:

  • Fire Protection Compliance Plan.

  • Certification Programme.

  • Means-of-Compliance Matrix.

  • Fire-Test Plan.

  • Fire-Test Specification.

  • Boundary-Condition Assessment.

  • Test-Article Representativeness Assessment.

  • Test Procedure.

  • Conformity Records.

  • Instrumentation and Calibration Records.

  • Burner Temperature Calibration Records.

  • Heat-Transfer-Rate Calibration Records.

  • Post-Test Validation Records.

  • Photographic and Video Records.

  • Test Deviation Records.

  • Fire-Test Report.

  • Certification Compliance Matrix.

  • Hazard Assessments.

  • System Safety Assessments.

  • Certification-Authority Correspondence.

How Success Is Measured

Requirement Compliance

Applicable regulatory and certification requirements are mapped to objective evidence.

Valid Calibration

The burner meets the required temperature and heat-transfer-rate conditions before testing and the applicable validation threshold after testing.

Test-Article Integrity

The test article satisfies the defined requirements for burn-through, flame penetration, leakage, ignition, load retention and residual flames.

Functional Performance

Every defined fire-intended function is maintained for the required duration or transitions to an approved safe state.

Traceability

The test report links the test article, drawings, configuration, boundary conditions, procedure, instrumentation, data and acceptance criteria.

Certification Acceptance

The applicant obtains acceptance of the fire-test evidence through the applicable certification process.

How Resonate Supports AS6826 Testing

Compliance Planning

Resonate supports the identification of applicable requirements, certification assumptions and proposed means of compliance.

Technical Interpretation

Resonate provides engineering interpretation of AS6826, FAA guidance, EASA requirements and related fire-test standards.

Boundary-Condition Development

Resonate supports assessment of aircraft operating envelopes and identification of representative or worst-case test conditions.

Test-Campaign Development

Support can include:

  • Test strategy.

  • Test-article definition.

  • Critical flame-location assessment.

  • Test matrix development.

  • Instrumentation requirements.

  • Test procedure development.

  • Pass/fail criteria.

  • Risk and contingency planning.

Burner and Calibration Support

Resonate can support the interpretation and application of temperature calibration, heat-transfer-rate calibration and post-test validation requirements.

Documentation Support

Support may include the preparation or independent review of:

  • Compliance plans.

  • Test plans.

  • Test specifications.

  • Test procedures.

  • Boundary-condition assessments.

  • Test reports.

  • Compliance matrices.

Independent Review

Independent technical review can identify gaps in representativeness, calibration, test severity, traceability and certification evidence before testing begins.

Certification Support

Resonate can support technical engagement with applicants, aircraft manufacturers, engine manufacturers, test laboratories and certification authorities. Authority acceptance remains the responsibility of the applicant and the relevant certification authority.

Frequently Asked Questions

What is AS6826?

AS6826 is an SAE Aerospace Standard providing fire-test methods, calibration requirements, boundary-condition guidance and pass/fail criteria for powerplant and propulsion-system components and installations.

When was AS6826 issued?

AS6826 was issued in April 2025.

Why was AS6826 created?

It was created to supplement FAA AC 20-135 Change 1 and reduce variation in powerplant fire-test methods, calibration, boundary conditions and acceptance criteria.

Does AS6826 replace FAA AC 20-135?

No. AS6826 significantly supplements the advisory circular. The applicable regulations, certification basis and agreed means of compliance still govern the project.

What standard flame does AS6826 require?

The standard flame has a minimum temperature of 2,000°F or 1,093°C and a minimum calibrated heat-transfer rate of 4,500 Btu/h or 1,319 W.

Is 4,500 Btu/h a heat-flux requirement?

No. Under AS6826, 4,500 Btu/h is the minimum heat-transfer rate measured using the prescribed copper-tube apparatus. It should not be described as a heat-flux density value.

What is the difference between fire resistant and fireproof?

Fire-resistant testing requires a minimum five-minute flame exposure. Fireproof testing requires a minimum 15-minute flame exposure. The applicable fire-intended functions and pass/fail criteria must also be satisfied.

Are operational loads required during testing?

Where applicable, yes. The applicant must assess vibration, load, pressure, airflow, fluid conditions, function, rotational speed and other installation-specific boundary conditions.

Is vibration always required?

Induced vibration is normally required unless the test article meets the defined exclusion criteria or the certification authority accepts an alternative justification.

Must the burner be calibrated before every test?

Pre-test flame-temperature and heat-transfer-rate calibration is required. Burner settings must then remain unchanged through the test and post-test validation.

Is post-test validation required?

Yes. Heat-transfer-rate validation must be completed before the burner is shut down. The applicable minimum is 4,500 Btu/h for a cleaned tube or 4,100 Btu/h where the tube cannot be cleaned without shutting down the burner.

Does AS6826 apply only to engine components?

No. Its scope includes powerplant and APU components and installations, including firewalls, nacelle hardware, fluid systems, controls, electrical equipment, fire detectors and related assemblies.

Can historical test evidence still be used?

Potentially. Acceptance by similarity, analogy or previous evidence depends on the applicable requirements, configuration similarity and certification-authority acceptance.

Does compliance with AS6826 guarantee certification approval?

No. The certification authority must accept the project-specific compliance strategy, test conditions, deviations and evidence.

Fire Protection and Certification

  • Fireproof vs Fire Resistant Components.

  • FAA AC 20-135 Explained.

  • ISO 2685 Fire Testing.

  • Aircraft Engine Fire-Protection Certification.

  • Aircraft Firewalls and Designated Fire Zones.

Fire-Test Methods

  • Burner Calibration Best Practice.

  • Heat-Transfer-Rate Validation.

  • Fluid-Handling Component Fire Testing.

  • Fire-Detection System Qualification.

  • Firewall Sealant Flame-Penetration Testing.

  • Fire-Test Boundary-Condition Assessment.

Powerplant Safety

  • Aircraft Engine Fire Protection.

  • Fire Detection and Extinguishing Systems.

  • Propulsion-System Safety Assessment.

  • Nacelle Fire Protection.

  • Engine Component Qualification Testing.

  • Fire-Test Evidence for Certification.

Call to Action

Need guidance on AS6826 certification testing?

Helios provides independent support for powerplant fire-test strategy, AS6826 interpretation, boundary-condition development, test planning, procedure preparation, evidence review and certification engagement.

Develop the compliance strategy before committing hardware and test time. Early technical review can expose weak assumptions, unrepresentative conditions and incomplete acceptance criteria before they become expensive programme problems.

Your Test Facilitator. Not simply a test facility.

Frequently Asked Questions About AS6826.pdf

What is AS6826?

AS6826.pdf is the SAE Aerospace Standard that defines harmonised fire test methods, burner calibration requirements, boundary conditions, and pass/fail criteria for aircraft powerplant and propulsion system fire testing. It was developed by the SAE A-22 Fire Protection and Flammability Testing Committee following an FAA request to supplement AC_20-135_with_change_1.pdf.

Why was AS6826 created?

AS6826 was developed to eliminate inconsistencies that existed across historical guidance documents and certification programmes. Before AS6826, different organisations often used different burner setups, calibration methods, test conditions and acceptance criteria. The standard provides a common industry framework accepted by certification authorities.

What problem does AS6826 solve?

AS6826 standardises:

  • Burner calibration procedures
  • Flame temperature requirements
  • Heat transfer requirements
  • Test boundary conditions
  • Fire-resistant and fireproof test methodologies
  • Pass/fail criteria
  • Test reporting requirements

This reduces certification uncertainty and improves the repeatability of fire testing between facilities and programmes.

What is the standard flame specified by AS6826?

AS6826 requires a standard flame with:

  • Minimum temperature: 2000°F (1093°C)
  • Minimum heat transfer rate: 4500 BTU/hr (1319 W)

Both temperature and heat transfer rate must be calibrated before each test.

What is the difference between Fire Resistant and Fireproof?

Fire Resistant

A component must continue to perform its intended function while exposed to a standard flame for a minimum of 5 minutes.

Fireproof

A component must continue to perform its intended function while exposed to a standard flame for a minimum of 15 minutes.

Does AS6826 replace FAA AC 20-135?

No.

AS6826.pdf was developed to supplement and expand guidance contained within AC_20-135_with_change_1.pdf. AS6826 provides more prescriptive test methodologies, calibration requirements and pass/fail criteria than the Advisory Circular alone.

What types of components does AS6826 apply to?

The standard applies to a wide range of propulsion system hardware including:

  • Firewalls
  • Nacelle structures
  • Fluid handling components
  • Fuel system components
  • Oil system components
  • Air system components
  • Shut-off valves
  • Fire detection systems
  • Fire extinguishing systems
  • Electrical controls
  • Electronic engine controls
  • Mechanical control systems
  • Auxiliary power unit components (APU)

Does AS6826 require testing under realistic operating conditions?

Yes.

One of the key principles of AS6826 is that testing should replicate operational aircraft conditions wherever possible. Boundary conditions may include:

  • Fluid pressure
  • Fluid flow
  • Fluid temperature
  • Mechanical loads
  • Differential pressure
  • Vibration
  • Rotational speed
  • Functional operation

The objective is to ensure the test represents real service conditions.

What are boundary conditions in AS6826?

Boundary conditions are the operational loads and environmental factors applied during testing to replicate aircraft operation.

Examples include:

  • Vibration
  • Airflow
  • Fluid flow
  • Hydraulic pressure
  • Fuel pressure
  • Temperature
  • Structural loads
  • System actuation commands

AS6826 defines a structured methodology for identifying and justifying these conditions.

Why is burner calibration so important?

A fire test is only valid if the flame environment is controlled and repeatable.

AS6826 requires:

  • Pre-test temperature calibration
  • Pre-test heat transfer calibration
  • Post-test heat transfer validation

This ensures every test article experiences a consistent fire environment.

What burners are acceptable under AS6826?

AS6826 requires kerosene-based burners capable of producing the standard flame and heat transfer conditions.

Examples include burners derived from:

The use of propane burners for primary certification fire testing has been largely superseded following FAA studies demonstrating that kerosene burners provide a more representative fire environment.

Can a component pass if flames remain after testing?

Potentially, yes.

AS6826 recognises that limited residual flames can occur following burner removal.

Residual flames may be acceptable if:

  • They self-extinguish within two minutes
  • They do not compromise fire-intended functions
  • They do not create additional hazards
  • They do not spread across the component

All residual flames must be documented and justified.

What are the pass/fail criteria for firewalls?

Firewalls must demonstrate:

  • No burn-through
  • No unacceptable flame penetration
  • No backside ignition
  • Structural integrity maintained
  • Fire-intended functions maintained
  • Leakage within approved limits
  • Acceptable residual flame behaviour

Firewalls are among the most demanding certifications covered by AS6826.

How does AS6826 treat fire detection systems?

Fire detector systems must:

  • Detect fire conditions correctly
  • Continue functioning during exposure
  • Meet applicable detection performance requirements
  • Annunciate fire conditions appropriately
  • Clear alarms correctly after removal of the fire source

The fire-intended function of the detector system must be maintained throughout the required fire exposure duration.

How does AS6826 address fuel, oil and hydraulic systems?

Fluid-carrying components must:

  • Resist flame exposure
  • Maintain required functionality
  • Prevent hazardous leakage
  • Maintain shut-off capability where applicable
  • Meet pressure and flow requirements during testing

Certain shut-off valves must also demonstrate continued sealing performance after closure during a fire event.

Is vibration required during fire testing?

Often, yes.

AS6826 recognises that vibration can influence fire performance by:

  • Breaking insulation layers
  • Damaging seals
  • Causing leakage
  • Affecting fasteners
  • Influencing moving components

The standard provides guidance on when vibration should be included and acceptable vibration levels.

How does AS6826 support certification?

AS6826 provides certification teams with:

  • Accepted fire test methods
  • Standardised calibration procedures
  • Defined compliance criteria
  • Consistent reporting requirements
  • Authority-recognised methodologies

This reduces programme risk and simplifies demonstration of compliance with FAA and EASA fire protection requirements.

What is the most significant benefit of AS6826?

The greatest benefit of AS6826.pdf is the creation of a single, modern and internationally harmonised framework for aircraft powerplant fire testing.

By combining decades of knowledge from:

the standard provides a repeatable and regulator-accepted route for demonstrating aircraft fire safety.

SEO Bonus Questions

  • What flame temperature is required by AS6826?
  • What is the difference between fireproof and fire-resistant testing?
  • Does AS6826 replace ISO 2685?
  • How is burner calibration performed under AS6826?
  • Which aircraft components require fireproof testing?
  • How are firewalls evaluated under AS6826?
  • What are AS6826 boundary conditions?
  • What is considered a hazardous fluid leak during testing?
  • How does AS6826 support FAA certification?
  • What are the common causes of fire test failure?

These long-tail questions align closely with likely search-engine queries from aerospace certification engineers and fire test specialists.

Technical Source Basis

  • AS6826, issued April 2025.

  • FAA AC 20-135 Change 1.

  • ISO 2685:1992.

  • FAA Power Plant Engineering Report No. 3A, 1961 version.

  • FAA Powerplant Engineering Report No. 3A, revised March 1978.

  • SAE AIR1377.

  • SAE AS8028.

  • SAE AS5127/2C.

AS6826 Powerplant Fire Test Standard