The Evolution of Powerplant Fire Testing: From Engineering Report 3A to AS6826

From FAA Engineering Report 3A to SAE AS6826, powerplant fire testing has evolved from prescribed equipment to performance-based verification, ensuring repeatable, representative, and certification-ready evidence of fire protection compliance.
UKAS

Scope Available

Cyber Essentials

Plus Certified

Battery Testing

Expertise

Independent

Test Evidence

Introduction

Powerplant fire testing has changed substantially over the past six decades.

Early methods concentrated on reproducing a severe flame environment around fluid-carrying aircraft components. Modern programmes must do much more.

They must control burner performance, thermal severity, test geometry, operating conditions, equipment function, boundary conditions, instrumentation, acceptance criteria and certification evidence.

The journey from FAA Powerplant Engineering Report No. 3A to SAE AS6826 reflects this progression.

It is not simply a history of burner designs.

It is the story of how aerospace fire testing developed from hardware-based instruction into a more repeatable, performance-focused and hazard-led engineering discipline.

Useful external references:
Reference standards:

The evolution in one minute

Period Development Central contribution
1961 FAA Powerplant Engineering Report No. 3A Standardised apparatus and hose fire-test procedure
Mid-1970s Original Lennox burner became unavailable Created a burner-equivalence and repeatability problem
1977 FAA-RD-76-213 Characterised burner performance and assessed alternatives
1978 Revised Engineering Report 3A Formalised alternative burners and performance controls
1970s onward SAE AS1055 and AIR1377 Converted FAA concepts into industry test and equipment standards
Later development ISO 2685 1992 and 1998 Provided an international aircraft fire-zone test framework
Legacy FAA guidance AC 20-135 and Change 1 Connected test methods with powerplant certification objectives (SAE AS401B propane burner dropped)
2018 FAA tasking to SAE Initiated development of a more harmonised standard
April 2025 SAE AS6826 issued Established a prescriptive powerplant fire-test framework
September 2025 FAA AC 20-135A issued Recognised AS6826 as an acceptable means of compliance

This is not a perfectly linear family tree.

Different documents served different products, authorities and applications. However, the technical continuity is clear. Repeatable thermal severity, representative conditions and defensible evidence became increasingly important.

1. The origins: Engineering Report No. 3A

FAA Powerplant Engineering Report No. 3A introduced a standard fire-test apparatus and procedure for flexible aircraft hose assemblies.

The test was not limited to placing a hose in a flame.

It attempted to represent several conditions that could influence hose performance:

  • a severe powerplant fire environment

  • operational fluid pressure

  • fluid flow

  • elevated fluid temperature

  • engine-related vibration

  • controlled airflow

  • defined burner position

  • representative hose mounting

The original procedure used a modified Lennox OB-32 conversion oil burner.

Its central technical features included:

  • a nominal 2,000°F fire environment

  • defined burner geometry

  • controlled hood airflow

  • vibration during exposure

  • fluid circulation under specified conditions

  • thermal calibration using a water-cooled copper-tube device

  • a minimum heat-transfer-rate requirement of 4,500 Btu/h

These controls represented a major advance.

The test environment was no longer defined only by visible flame or burner identity. It included measurable thermal performance and representative operating stresses.

Why the original test mattered

Flexible hoses and other fluid-system components can become part of the fire hazard.

A failed line may release fuel, oil or hydraulic fluid into an existing fire. The resulting leakage can increase fire intensity, extend the duration or allow the fire to spread.

The safety objective was therefore not merely:

Does the hose material burn?

The more important questions were:

  • Can the assembly contain its fluid?

  • Can it maintain the required function?

  • Does it resist leakage during fire exposure?

  • Does vibration create a failure path?

  • Can the system remain safe long enough for isolation or shutdown?

  • Does the component aggravate the existing hazard?

This is the foundation of hazard-minimisation thinking.

The component is judged by its contribution to aircraft safety, not only by its physical appearance after exposure.

2. Fire resistant and fireproof

Classification Typical minimum exposure Broad safety intent
Fire resistant 5 minutes Maintain the required function during the period needed to recognise, respond to and isolate the fire hazard
Fireproof 15 minutes Withstand the longer fire exposure required for components, structures or systems that must continue providing protection

The classification is not selected by the laboratory.

It follows from:

  • the applicable regulation

  • the aircraft or engine installation

  • the component function

  • the hazard assessment

  • the certification basis

  • the agreed compliance strategy

A five-minute exposure is not automatically suitable because a component is small.

A 15-minute exposure is not automatically required because the fire appears severe.

The applicable safety objective determines the classification. The standard defines how the selected requirement is demonstrated.

3. The burner availability problem

The original Report 3A procedure depended on the modified Lennox OB-32 burner.

By the mid-1970s, that burner was no longer commercially available.

This created a serious practical problem.

New laboratories could not simply purchase the prescribed equipment. Existing facilities faced maintenance and replacement risks. Manufacturers needed confidence that tests conducted using another burner would remain comparable with established certification evidence.

The problem could not be solved by selecting a burner that looked similar.

Different burners can produce different:

  • flame shapes

  • temperature distributions

  • heat-transfer rates

  • oxygen concentrations

  • fuel-air ratios

  • combustion stability

  • soot deposition

  • impingement patterns

The real requirement was not to reproduce the appearance of the Lennox burner.

It was to reproduce the fire environment.

4. FAA-RD-76-213: From burner identity to burner performance

FAA-RD-76-213, Re-evaluation of Burner Characteristics for Fire Resistance Tests, was commissioned to characterise the original burner and identify acceptable alternatives.

The investigation assessed measurable characteristics including:

  • flame temperature

  • temperature distribution

  • heat-transfer rate

  • flame geometry

  • thermal energy

  • oxygen concentration

  • burner stability

The research considered modified versions of burners including:

  • Carlin 200 CRD

  • Stewart-Warner HPR-250

  • Stewart-Warner FR-600

The most important change was philosophical.

The industry moved from asking:

Which burner model is named?

to asking:

Does the burner produce the required thermal environment?

That is the essence of performance-based equipment qualification.

A listed burner model is not automatically compliant. Its modification state, operating settings, geometry and measured output must be controlled.

Similarly, an alternative burner is not automatically unacceptable. It may be suitable if its performance is demonstrated against the governing criteria.

5. Engineering Report 3A revision, 1978

The revised March 1978 Engineering Report incorporated the burner-characterisation work.

It retained the test’s original purpose while providing a route for using alternative modified burners capable of producing the required flame characteristics.

The revision addressed:

  • acceptable burner arrangements

  • burner modification

  • flame-temperature profiles

  • heat-transfer-rate performance

  • burner positioning

  • airflow

  • vibration

  • fluid-system operating conditions

  • test sequence

  • calibration or standardisation activity

This reduced dependence on one obsolete item of commercial hardware.

More importantly, it preserved the technical intent of the test.

The principle remains relevant:

Certification continuity should be protected by controlling performance, not by preserving obsolete equipment for its own sake.

Burner qualification is not the same as daily verification

The Report 3A lineage reveals two related but distinct activities.

Burner-configuration qualification

This demonstrates that a burner design, modification and setup can reproduce the required flame characteristics.

Operational standardisation or verification

This confirms that the actual burner achieves the required output before use in a test campaign.

The distinction matters.

Owning a Carlin 200 CRD does not prove that the burner:

  • has the correct modifications

  • is correctly maintained

  • uses the required nozzle

  • operates at the correct fuel and air settings

  • produces the required flame profile

  • meets the heat-transfer requirement

  • is positioned correctly

  • remains stable during testing

Burner identity is only one part of test-equipment control.

6. SAE AS1055 and AIR1377

FAA research and Report 3A practice influenced industry standards addressing hose and fluid-system fire testing.

SAE AS1055

SAE AS1055 addresses fire testing of:

  • flexible hose assemblies

  • tube assemblies

  • coils

  • fittings

  • similar system components

It translated the hose-test philosophy into an industry standard that could be applied through customer specifications, Technical Standard Orders and certification programmes.

SAE AIR1377

SAE AIR1377 addresses fire-test equipment for flexible hose and tube assemblies.

It covers matters such as:

  • burner designs

  • airflow hood arrangements

  • vibration equipment

  • heat-transfer-rate measurement

  • burner conversion details

  • equipment setup

Together, these documents helped laboratories reproduce a recognised fire-test environment without relying solely on informal facility knowledge.

However, they should not be treated as universal methods for every modern powerplant component.

Their relevance depends on the article, applicable standard, certification basis and approved test plan.

7. ISO 2685 and the international fire-zone framework

ISO 2685 provides an international environmental test procedure for aircraft components, equipment and structures installed in designated fire zones.

Its framework includes:

  • standard flame requirements

  • fire-resistant and fireproof classifications

  • defined exposure periods

  • burner calibration

  • test-article configuration

  • operating conditions

  • vibration where applicable

  • functional monitoring

  • pass criteria

ISO 2685 shares broad technical principles with FAA powerplant fire-testing practice.

These include:

  • severe controlled flame exposure

  • measured thermal performance

  • defined duration

  • representative mounting

  • operational conditions

  • functional requirements

  • repeatable evidence

However, similar objectives do not establish technical equivalence.

ISO 2685 and FAA or SAE methods can differ in:

  • burner types

  • calibration terminology

  • measurement equipment

  • heat-transfer definitions

  • article dimensions

  • vibration requirements

  • component-specific methods

  • acceptance criteria

  • reporting expectations

ISO 2685 forms part of the wider historical framework. It should not be described as the direct origin of every later SAE requirement.

8. AC 20-135: Connecting test methods to certification

FAA AC 20-135 expanded the discussion beyond flexible hose assemblies.

It provided guidance for demonstrating fire-protection compliance for powerplant installations and propulsion-system components.

The Advisory Circular addressed matters including:

  • fireproof and fire-resistant requirements

  • standard fire severity

  • burner selection

  • flame coverage

  • representative operating conditions

  • fluid pressure and flow

  • structural loading

  • vibration

  • airflow

  • component function

  • installation-specific boundary conditions

  • acceptance criteria

  • certification documentation

This was an important development.

Engineering Report 3A principally described apparatus and a test procedure. AC 20-135 connected laboratory activity to the regulatory safety objective.

The central question became:

Does the test provide evidence that the component or installation satisfies the applicable fire-protection requirement?

That connection prevents the test standard from being treated as the certification requirement itself.

Regulations establish the required safety outcome. Advisory material and test standards provide methods for generating evidence. The applicant, certification authority and approved compliance strategy determine whether that evidence is acceptable.

9. Why historical variation became a problem

AC 20-135 provided valuable guidance, but programmes could still differ in their interpretation and implementation.

Differences could arise in:

  • burner configuration

  • flame calibration

  • flame positioning

  • test-article dimensions

  • fixture design

  • heat sinks

  • pressure and flow conditions

  • vibration requirements

  • airflow

  • load application

  • functional monitoring

  • pass and fail criteria

  • post-test burner verification

  • reporting content

These differences could create technically significant variation between laboratories and certification programmes.

A component tested in one facility might not receive the same thermal exposure, boundary conditions or acceptance assessment in another.

The consequences could include:

  • repeated testing

  • additional certification issue papers

  • disagreement over test validity

  • difficulty reusing legacy data

  • increased programme cost

  • inconsistent severity

  • delayed certification decisions

This did not mean that historical testing lacked value.

It meant the industry needed a more prescriptive framework capable of reducing avoidable variation while preserving the need for engineering judgement.

10. The 2018 FAA tasking to SAE

In March 2018, the FAA tasked SAE International with developing industry standards to supplement AC 20-135 Change 1.

The work was undertaken through the SAE A-22 Fire Protection and Flammability Testing Committee.

The development involved industry and aviation certification-authority participation.

The objective was not merely to rewrite the existing Advisory Circular.

The new standard needed to address:

  • burner requirements

  • flame-temperature control

  • heat-transfer-rate measurement

  • calibration equipment

  • calibration procedures

  • test-article representativeness

  • boundary-condition selection

  • operating conditions

  • instrumentation

  • component-specific acceptance criteria

  • reporting and evidence requirements

This marked another important transition.

Powerplant fire testing was moving from broad guidance and programme precedent towards one more consistent laboratory framework.

11. SAE AS6826: The modern framework

SAE AS6826, Powerplant Fire Test Standards, was issued in April 2025.

It provides a structured framework for powerplant and Auxiliary Power Unit components and installations.

Its scope includes hardware such as:

  • firewalls and shrouds

  • nacelle and cowling components

  • fluid-handling components

  • hoses, tubes and fittings

  • controls and shut-off valves

  • fire seals and penetrations

  • fire-extinguishing lines

  • electrical wires and connectors

  • electronic engine controls

  • mechanical control systems

  • fire-detection equipment

AS6826 addresses several areas where historical programmes could differ.

Standard flame

The standard flame requires:

  • a minimum temperature of 2,000°F or 1,093°C

  • a minimum heat-transfer rate of 4,500 Btu/h or 1,319 W

The 4,500 Btu/h value is a heat-transfer-rate requirement measured using the prescribed water-cooled copper-tube apparatus.

It should not be described as heat-flux density.

Temperature calibration

The temperature-calibration method uses a defined thermocouple rake and controlled recording requirements.

The purpose is to demonstrate that the burner produces the required temperature distribution rather than one isolated hot point.

Heat-transfer calibration

The burner must demonstrate the prescribed heat-transfer rate before testing.

Post-test validation then provides evidence that burner performance remained acceptable through the exposure.

Representative test articles

The hardware should represent the production design, materials, thicknesses, joints, penetrations, manufacturing features, installation interfaces and relevant heat paths.

Boundary conditions

Depending on the component, the test plan may need to address:

  • vibration

  • structural load

  • fluid pressure

  • fluid flow

  • fluid temperature

  • differential pressure

  • airflow

  • rotational speed

  • electrical loading

  • commanded operation

  • shutdown function

  • reservoir quantity

  • mounting orientation

Component-specific criteria

AS6826 does not use one universal pass criterion.

The applicable criteria may include:

  • burn-through

  • flame penetration

  • backside ignition

  • maintained structural load

  • leakage

  • gapping

  • residual flame

  • continued fire-intended function

  • commanded closure

  • safe engine shutdown

This is a major improvement over treating every component as though the same visual inspection could determine success.

12. AC 20-135A and recognition of AS6826

FAA AC 20-135A was issued in September 2025.

It recognises SAE AS6826 as an acceptable means of compliance for applicable powerplant and propulsion-system fire-protection requirements.

It also cancels AC 20-135 Change 1.

This creates an important relationship:

Document Role
Document Role Airworthiness regulations Establish the required safety outcome
FAA AC 20-135A Provides FAA guidance and identifies acceptable compliance approaches
SAE AS6826 Provides detailed powerplant fire-test methods and criteria
Qualification test plan or procedure Applies the method to the particular component and installation
Test report and evidence package Records what was tested, how it was tested and what happened
Certification finding Determines whether the evidence supports compliance

AS6826 is therefore an important modern test standard.

It is not a regulation.

It does not automatically approve a component, engine or aircraft installation.

Certification acceptance still depends on:

  • the applicable requirements

  • the approved means of compliance

  • the test configuration

  • the boundary conditions

  • the acceptance criteria

  • conformity

  • deviations

  • authority review

A successful test report supports certification. It does not itself grant certification.

What changed from Report 3A to AS6826?

Area Earlier approach Modern AS6826 direction
Test equipment Prescribed apparatus and named burner configurations Controlled burner configuration meeting defined performance requirements
Thermal severity Temperature and water-cooled copper-tube measurement Detailed temperature and heat-transfer-rate calibration
Burner alternatives Addressed through characterisation and equivalence studies Burner acceptability tied to defined standard-flame performance
Test article Strong focus on hose assemblies and related hardware Wider range of powerplant and APU components and installations
Operating conditions Pressure, flow, temperature, vibration and airflow Structured boundary-condition assessment covering relevant service conditions
Acceptance criteria Product or programme dependent More detailed component-specific criteria
Documentation Apparatus, procedure and result records Controlled planning, calibration, conformity, data, deviations and reporting
Certification role Test procedure supporting FAA evidence Prescriptive method recognised through current FAA guidance
Engineering philosophy Reproduce a severe fire and observe performance Reproduce a controlled hazard while demonstrating defined fire-intended functions

The development is significant, but the core engineering objective has remained consistent.

The test must expose representative hardware to a severe and controlled fire environment while applying the operating conditions that could influence safety performance.

What AS6826 does not change

A more prescriptive standard does not remove the need for engineering judgement.

The applicant must still determine:

  • which regulations apply

  • whether the component must be fire resistant or fireproof

  • what function must be maintained

  • which fire source and direction are critical

  • what installation conditions are representative

  • which boundary conditions create the worst case

  • what constitutes failure

  • what evidence the authority requires

  • whether legacy data remains applicable

More severe is not automatically more correct.

A test can be excessively severe yet unrepresentative. It can also be insufficiently severe because important operating loads, fluids, airflow or interfaces were omitted.

The correct test is the one that credibly represents the applicable hazard and generates evidence against the required safety objective.

Why this history matters

The history of powerplant fire testing provides several practical lessons.

Burner appearance is not burner performance

A visible flame is not sufficient evidence of a valid fire environment.

Temperature alone is not enough

A burner can achieve a high temperature without transferring the required thermal energy to the article.

One hot point does not define the flame

The temperature distribution and flame coverage affect the component response.

Installation conditions matter

Pressure, flow, vibration, load, airflow, mounting and function can change the failure mechanism.

Calibration is part of the evidence

Pre-test calibration and post-test validation are not administrative details. They support the technical validity of the exposure.

The standard does not select the requirement

The certification basis and hazard assessment determine what must be demonstrated.

A pass does not automatically mean approval

The final evidence must still be accepted within the applicable certification or qualification process.

The enduring engineering principle

From Report 3A to AS6826, the equipment, calibration methods and documentation requirements have evolved.

The central safety principle has not.

A powerplant fire test must demonstrate that a component or installation can perform its required safety function during a credible fire hazard without creating an unacceptable additional risk.

That requires more than a burner.

It requires:

  • a controlled thermal environment

  • representative hardware

  • realistic operating conditions

  • defined fire-intended functions

  • measurable acceptance criteria

  • traceable instrumentation

  • disciplined execution

  • defensible evidence

The evolution of powerplant fire testing is therefore not simply a progression from one document to another.

It is the progression from prescribed hardware towards controlled performance, representative hazards and evidence that can withstand technical and certification scrutiny.

Understand the hazard. Control the fire environment. Represent the installation. Demonstrate the required function.

Your Test Facilitator. Not simply a test facility.

Replicating real-world conditions in one location.

Resonate testing provides high quality fire, mechanical, and environmental test solutions and certification services across a wide range of industrial sectors. From Primes to SME’s, Resonate Testing provides a bespoke and tailored service to our clients.

Send your flammability requirements for engineer review

Use the contact route to share the requirement, test profile, drawings or specification for review.

Contact Form

Whether you’re looking to contact us for the first time or have another testing requirement,  we’d love to hear from you.